LOAD CENTERS, ASSOCIATED CIRCUIT BREAKERS, AND ACCESSORIES, BUYLOG SECTION 1

1-8

— PowerMark PRO load centers

Main lug, factory installed, indoor (NEMA 1) enclosure, top/bottom feed 1

1 pole, 1” spaces

2 pole, 1” spaces

Total 1-pole spaces

Max single pole circuits

Main wire size (AWG/kcmil) Cu-Al

Front type

Equipment ground kit

Ordering code

Main ampere rating

125

12 24 32 32 40 42

6

12 24 32 32 40 42

24 48 64 64 80 84

Combination Combination Combination Combination Combination Combination

6-2/0 TGK12 and TNLK20 installed 6-2/0 TGK 24 and TNLK20 installed 6-2/0 TGK32 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed 1-300 TGK42 and TNLK20 installed

PLM1212C 2 PLM2412C 2 PLM3212C 2 PLM3220C 3 PLM4020C 3 PLM4222C 3

12 16 16 20 20

200

225

1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.

Main lug, factory installed, indoor (NEMA 1) enclosure, top/bottom feed, white trim 1

1 pole, 1” spaces

2 pole, 1” spaces

Total 1-pole spaces

Max single pole circuits

Main wire size (AWG/kcmil) Cu-Al

Front type

Equipment ground kit

Ordering code

Main ampere rating

125

12 24 32 32 40 42

6

12 24 32 32 40 42

24 48 64 64 80 84

Combination Combination Combination Combination Combination Combination

6-2/0 TGK12 and TNLK20 installed 6-2/0 TGK 24 and TNLK20 installed 6-2/0 TGK32 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed 1-300 TGK42 and TNLK20 installed

PLM1212W 2 PLM2412W 2 PLM3212W 2 PLM3220W 3 PLM4020W 3 PLM4222W 3

12 16 16 20 20

200

225

1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.

Main lug, factory installed, outdoor (NEMA 3R) enclosure, top/bottom feed 1

1 pole, 1” spaces

2 pole, 1” spaces

Total 1-pole spaces

Max single pole circuits

Main wire size (AWG/kcmil) Cu-Al

Front type

Equipment ground kit

Ordering code

Main ampere rating

125 200

24 32 40

12 16 20

24 32 40

48 64 80

– – –

6-2/0 TGK24 and TNLK20 installed 6-250 TGK32 and TNLK20 installed 6-250 TGK42 and TNLK20 installed

PLM2412R 2 PLM3220R 3 PLM4020R 3

1 PLM indicates units are convertible to main breaker 2 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43 3 For main breaker, order THQMVXXXE circuit breaker from page 1-48.

NOTE: Circuit breakers must be ordered separately. Click here.